Exemplar: MIDA-100B

Ratum Current: 16A, 25A, 32A, 40A, 63A, 80A 100A
Poleni: 2Pole (1P+N) , 4Pole (3P+N)
Ratum voltage: 2Pole: 230V/240V , 4Pole: 400V/415V
Rated frequency: 50/60Hz
Ratum residua operandi vena: 30mA,100mA,300mA
Brevis cursus current Inc = I c 10000A
Standard: IEC 61008-1 , IEC 62423
RCD Type B 40A 30mA DC 6mA et RCCB Type B 63A 30mA DC 6mA
Type B RCD 40A 4Pole 2Pole 30mA for EV Charger Station

Product Detail

Product Tags

 

Typus B sunt universales venae sensitivae residuae currentis circa praevaricatores RCCBs destinati ad applicationes industriales in quibus crescit usus machinorum sicut convertentium frequentiae, instrumentorum medicorum et systematum UPS.In RCCB Type B vitia tutanda facta sunt propter excursus residuales DC lenis vel excursus cum tremore residuo, quae in applicationibus superioribus sunt communes.

Typus regularis A/AC RCCBs hasce DC excursus residuas deprehendere nequeunt.Praeter has excursus teretes DC residuos faciunt Typus cogitationes in excursus residuos sentientes ac pulsantes DC currentes residuos qui altiorem periculum pro salute in talibus institutionibus conficiunt.Cum usuTypus B RCCBs in tali applicatione plenam tutelam ad totam institutionem praestare possumus.Hac de causa, considerantur cogitationes universales currentes, dum tutelam praebent contra omnes possibilis ludificationes waveformes quae in norma EN 62423 recensita sunt.

Features electrica

Exemplar MIDA-100B
Type (unda forma terrae lacus sentitur) B Type RCCB
In current rated 25A, 32A, 40A, 63A, 80A, 100A .
Poloni 2Pole et 4Pole
Rated voltage Ue 2Pole: 230V / 240V , 4Pole: 400V / 415V
Nulla voltage Ui 500V
Rated frequency 50/60Hz
Rated residua operandi vena (I n) 30mA,100mA,300mA
Rated RELICTUM faciendi et frangendi facultatem (I m) 500(In=2540A) 630(In=63A)
Brevi-circuitus current Inc = I c 10000A
SCPD fuse 10000
Intermissum tempus sub I n ≤0.1s
Ratum impetus sustinere voltage (1.5/50) Uimp 4000V
Dielectrica test voltage in ind.Freq.quia 1min 2.5kV
Vita electrica 2,000 Cycles
Mechanica vita 4,000 Cycles

Institutionem

Contact situ indicator Ita
Praesidium gradum IP20
Ambiens temperatus (per cotidie average≤35°C) -5°C~+40°C
Repono temperatus -25°C~+70°C
Terminatio nexu generis Cable/pin-type busbar/U-type busbar
Terminatio magnitudinis top / imo ad funem 25mm218-3AWG
Terminatio magnitudinis top / imo ad Busbar 25mm218-3AWG
tensus tensus 2.5Nm 22In-lbs
Adscendens On DIN rail EN60715(35mm) per ieiunium tonde fabrica
Connection A summis

Ludentibus Current dolor

Angulus pigri I n>0.01A ego n≤0.01A
0.35I n≤I≤1.4I n 0.35I n≤I ≤2I n
90° 0.25I n≤I≤1.4I n 0.25I n≤I ≤2I n
135° 0.11I n≤I≤1.4I n 0.11I n≤I ≤2In
Forma detectable undam Pulsans directum current sensitivo Surge current probationem
B classis
Impulsu providetur pro excursus residuales sinusoidales AC currentes residuales pulsante, alternantes currentes sinusoidales residuos usque ad 1000Hz, currentes directos residuales pulsantes et pro currentibus residuobus directis laevibus, sive subito sive tardius increscentibus applicati.
RCD.jpg
Agunt AC et pulsantes DC culpa venae quae ad 0 vel fere 0 intra unum tempus maioris frequentiae.
rccb.jpg
RCCBassurgat facultatem.
Non supplantant in normatis 8/20 υs fluctuum fluctuum acc.to VDE 0432 Pars 2 cum fluctu currente valores usque ad 250A.

Circuitus Diagram

Typus B RCD.jpg

Bonitas bona suppeditare potuimus, sumptus infestos et optimi emptoris subsidia.Societas nostra fabrum idoneos et technicos habet ut tuis quaestionibus de tuenda quaestionibus, communi aliquo defectu, respondeat.Nostra producta qualitas certitudine, concessionibus pretio, quaestionibus circa res supellectilis, Vide ut liberum contactus nos sentiat.

 


  • Previous:
  • Deinde:

  • Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte nobis
    • Sequere nos:
    • facebook
    • linkedin
    • twitter
    • youtube
    • instagram

    Epistulam tuam relinque:

    Epistulam tuam hic scribe et mitte nobis